Industrial keyboards with embossed membrane keypad, housed in a NEMA 4X enclosure. Designed for industrial or hazardous applications, keyboard can be designed to fit desktop or panel mounted with or without integrated pointing device. Available models with FM Approvals for Division 1 and Division 2 environments.

Unit of Measure

Standard Features and Benefits

Ratings

N/A

Division 2

Materials

Enclosure

N/A
  • FM Approved Non-Incendive Models for Hazardous Locations rated Class I, II, & III, Division 2, Group A-D, F and G or Class I, II & III, Division 1&2, Group C-G
  • Sealed Lemo™ Connectors
  • Built in NEMA 4X, Non-Incendive or Intrinsically Safe Pointing Devices
  • KVM (Keyboard/Video/Mouse) extender, up to 32,000 ft of separation between local & remote

Design

N/A Non-Incendive Division 2, Desktop

Physical Dimension

Dimensional Drawing

N/A 6940NI Drawing

Height

N/A 2.40 in

Width

N/A 21.40 in

Depth

N/A 8.20 in

Weight

N/A 10 lb

Environmental

Desktop Non-Condensing Relative Humidity

N/A 10 to 95 %

Panel Mount Non-Condensing Relative Humidity

N/A 20 to 80 %

Operating Temperature

N/A 0 to 55 ºC32 to 131 ºF

Storage Temperature

N/A -40 to 85 ºC-40 to 185 ºF

Overlay Material

N/A Polycarbonate with Hard Coat

Mean Time between Failures (MTBF)

N/A 3 Million Keystrokes

Power

Direct Current (DC) Voltage Supply from Keyboard Port or PS/2 Mouse Port

N/A 5 V

Direct Current (DC) Voltage Supply from Serial Mouse Port

N/A 12 V

Maximum Current Draw (NEMA)

N/A 200 mA

Maximum Current Draw (I.S.)

N/A 15 mA

Cable

Keyboard Connector

N/A 6-Pin Mini DIN

Pointing Device Connector

N/A PS/2 - 6-Pin Mini DIN Serial - DB9 Receptacle USB - 4-Pin USB Type A

Length

N/A 6 ft

Membrane Keyboard Overlay Chemical Resistance

Resistant To

N/A Ethanol Acetone Cutting Oil Xylene Nitric Acid <10% Isopropanol Benzene Silicon Oil Methanol Cyclohexanol Methyl Ethyl Ketone Turpentine Substitute Washing Powders Brown Castor Oil Fluorochlorohydrocarbons Phosphoric Acid <30% Sodium Hypochlorite <20% Hydrochloric Acid <10% Glycol Ammonia <2% Acetaldehyde Formic Acid <50% Alkali Carbonate Trichloroethane Caustic Soda <2% Bichromate Perchloroethylene 1-1-1 Trichloroethane Potassium Carbonate Aliphatic Hydrocarbons Acetic Acid <5% Potassium Ferricyanide Ethyl Acetate Fabric Conditioners Hydrogen Peroxide <25% Potassium Ferrocyanide Glycerin Diesel Oil Gasoline Dioxin Paraffin Oil Diethyl Ether Linseed Oil Toluene

Slight Discoloration May Result

N/A Ketchup Lemon Juice Tomato Juice

Brown Discoloration May Result

N/A Tincture of Iodine

Substances to be Avoided

N/A Benzyl Alcohol Concentrate Caustic Solutions Concentrated Mineral Acids Methylene Chloride Pressure Steam >100%

Options

Options

N/A

930 - Sealed NEMA 4X Connector for Pointing Device on Desktop Keyboard (Non-I.S. Models Only)

Accessories

N/A 9148 - Current Limiter Kit (Non-Incendive Models Only)

Additional Information

Additional Information

N/A

Please note that all Daisy Data Displays equipment with pointing devices is no longer differentiated between Serial and PS/2. All models are now universal - the model numbers now end in UN. However, You must differentiate between Serial and PS/2 for I.S. Isolators.

Note

Note

N/A

Please note that all Daisy Data Displays equipment with pointing devices is no longer differentiated between Serial and PS/2. All models are now universal - the model numbers now end in UN. However, You must differentiate between Serial and PS/2 for I.S. Isolators.

Series

N/A 6900